Approving a detachable container house sample requires more than checking its appearance. The unit should be measured, operated, assembled, folded, and reviewed against the approved technical specification. Key inspection areas include dimensions, structural joints, galvanized protection, wall and roof panels, flooring, drainage, doors and windows, electrical installation, lifting points, transport performance, and supporting documents.
Begin by comparing the physical sample with the approved drawing and purchase specification. The standard unit is listed at 6055 mm long, 2435 mm wide, and 2800 mm high, with a clear internal height of 2500 mm. Depending on the project, the product may be supplied as a 3 m × 6 m unit, a 4 m × 6 m unit, a double-wing expandable model, or a combined arrangement extending to 12 m. Measure each relevant dimension and record any deviation before approval.
Review the complete load-bearing system, including the 140 × 140 mm hot-dip galvanized square-tube columns, Q355 high-strength steel specified for export models, galvanized cold-formed main beams, and secondary beams spaced at 400 mm. Check the dimensional accuracy of the frame, connection alignment, bolt fit, lifting holes, and any welds used during production.
Pay special attention to the thickened cast-steel folding hinges and the eight 8 mm cast-steel corner castings supplied for each set. Hinges should move evenly without excessive play, binding, or cracking. Corner fittings must be aligned and free from distortion. Since the stated installation method uses bolted assembly without on-site welding, confirm that all required holes, fasteners, and connection plates are ready for installation without field modification.
Examine the treatment of all exposed steel surfaces. The documented process consists of pickling, phosphating, and electrostatic powder coating, with a stated coating thickness of at least 60 μm. Inspect corners, cut edges, hinge areas, fasteners, lifting points, and concealed or difficult-to-reach surfaces for thin coverage, scratches, exposed steel, or early corrosion.
The roof should also be tested with water rather than reviewed only visually. Confirm that the hidden drainage grooves are continuous and that the built-in downpipes in the four corner posts discharge water away from the enclosure. A water-flow test can reveal blocked channels, poor slope, leaking joints, or water entering the wall and ceiling system.
Confirm that the sample contains the panel core selected in the contract. Available wall and roof cores include EPS, rock wool, and PU. The panels use double-sided 0.4–0.5 mm anti-fingerprint color-coated galvanized steel sheets. Inspect the surface finish, panel width, joint alignment, edge sealing, insulation continuity, and any dents or coating damage.
Inspect the floor from both the finished surface and the supporting structure. The listed system uses a galvanized square-tube support grid with an 18 mm cement fiber board or MGO board. Where specified, verify the PVC floor leather or anti-slip ceramic tile, including its bonding, edge treatment, flatness, and resistance to movement during folding and transport.
Operate the 960 × 2100 mm steel security door repeatedly. The leaf should close squarely, the lock and anti-theft handle should work smoothly, and the frame should remain stable. For the aluminum alloy sliding windows, check tempered-glass condition, opening movement, seals, drainage, hardware, and fly-screen installation.
Inspect the electrical system before the walls are closed or the unit leaves the factory. Test the LED ceiling lights, power sockets, distribution box, switches, cable routing, and concealed conduits. The electrical arrangement is described as adaptable to markets in Southeast Asia, North America, and South America. The approval record should therefore identify the selected country or region and the applicable voltage, frequency, plug, and safety requirements.
Observe the complete folding and unfolding cycle under controlled conditions. The published data indicates that two workers can assemble the standard unit in approximately 10–15 minutes without heavy machinery. Record the actual labor, time, tools, and number of adjustments required. The sample should fold without interference, retain panel alignment, and allow bolts to be installed without drilling or cutting.
Review the product in its transport condition as well. Confirm that stacking points are stable, lifting locations are clearly defined, and no panels, hinges, windows, or electrical components are damaged by repeated handling. The standard unit is reported to weigh approximately 1300–1500 kg, although the final figure depends on the selected configuration and finishes. Match the measured or documented weight with the planned loading method, shipping equipment, and site handling capacity.
Commercial and certification documents should support the inspection rather than replace it. The listed terms include factory self-inspection, a minimum order quantity of one set, a seven-day delivery time, and a one-year warranty excluding man-made damage. Confirm that these conditions apply to the exact approved configuration, including optional sizes, materials, electrical specifications, and finishes.
CE certification No. 3N240819.GUTQO66 is stated to cover modular container house types such as folding and expandable units, with application regions including the EU, Australia, North America, South America, Southeast Asia, and the Middle East. Keep the certificate, factory inspection report, drawings, material list, test records, and warranty terms together with the signed sample approval record.
| Inspection category | Sample approval actions | Declared product information |
|---|---|---|
| Configuration and structure | Measure the unit, check internal clearance, inspect columns, beams, hinges, corner castings, lifting holes, and bolt connections. | Standard size: 6055 × 2435 × 2800 mm; 2500 mm clear height; bolted assembly. |
| Surface protection and drainage | Inspect the coating, exposed edges, fasteners, hinges, roof channels, and downpipes; complete a water-discharge test. | Pickling, phosphating, and powder coating; minimum stated coating thickness of 60 μm; concealed roof drainage and four corner downpipes. |
| Envelope and floor | Confirm the chosen insulation core, panel joints, surface condition, support grid, board thickness, and finished floor. | EPS, rock wool, or PU cores; 18 mm cement fiber board or MGO board. |
| Doors, windows, and electrical work | Operate openings and examine glazing, screens, locks, lights, outlets, distribution equipment, and concealed wiring. | Steel security door; tempered-glass aluminum sliding windows; pre-installed electrical system. |
| Folding and logistics | Record folding and unfolding performance, assembly duration, labor, stacking stability, lifting behavior, and transport readiness. | Two workers and approximately 10–15 minutes stated for assembly; stackable design; approximately 1300–1500 kg standard weight. |
| Quality and commercial support | Cross-check the inspection report, destination market, delivery promise, warranty exclusions, and approved configuration. | Factory self-inspection; seven-day delivery; one-year warranty excluding man-made damage; MOQ of one set. |
Inspect the primary columns and beams, secondary beams, folding hinges, corner castings, bolts, lifting holes, and overall frame alignment. Hinge travel and connection fit are especially important because the house is intended to fold, relocate, and be assembled repeatedly.
Verify the selected panel core and sheet thickness, inspect joints and edge seals, review the floor assembly, and perform a controlled roof water test. Look for coating defects, standing water, leakage, blocked drainage channels, and water paths around the corner posts.
Document measured dimensions, configuration, selected materials, coating condition, visible defects, electrical details, door and window results, folding and stacking performance, assembly time, weight, factory self-inspection status, destination market, delivery terms, warranty limitations, and any corrective actions. The approved sample record should remain linked to the final production order.
A detachable container house sample should be approved only when its physical performance and documentation agree with the signed specification. The review should cover measurements, structural connections, corrosion protection, panels, flooring, drainage, openings, electrical services, folding operation, lifting, stacking, transport, and warranty support.
For procurement planning, the listed model supports a one-set minimum order, factory self-inspection, a stated seven-day delivery period, and a one-year warranty that excludes man-made damage. The unit is positioned for construction-site dormitories, project offices, field camps, temporary post-disaster accommodation, tourism and cultural commercial areas, and new rural villas. A reported Indonesian energy-company project involving 2,000 sets for mining-worker dormitories also highlights the importance of checking repeatability and installation workflow before a large deployment. For technical assistance, contact guizugroup@outlook.com.
Guangdong Uni-House Technology Co., Ltd. operates as a foreign trade company under the Guizu Group and provides design, research and development, manufacturing, installation, and after-sales services through several factories. Established in 2008, the company reports approximately 200 employees, a 30,000-square-meter production base, and annual capacity of 10,000 sets. Its resources include more than 30 engineers and designers, over 10 production lines, more than 200 sets of molds, and 150 utility model patents. Reported technical capabilities include structural analysis, fatigue-life evaluation, and airtightness testing. The company holds CE certification No. 3N240819.GUTQO66 and serves customers in several industries and international markets.

REPORT