How to Choose a Dry Type Transformer for Data Center Backup Power

VIP-User
2026-11-26

Selecting a dry type transformer for data center backup power starts with the approved load schedule and the facility’s electrical design. Capacity, voltage, frequency, cooling, insulation, connections, and redundancy requirements must work together. The listed three-phase transformer is available from 500 to 2,500 kVA, with customized ratings also offered. Confirm the final configuration through project calculations and approved technical drawings before placing an order.

Start With Backup Load and Redundancy Requirements

Identify the equipment that must remain powered during a supply interruption, then review how that demand is distributed across the planned backup configuration. Data and computing centers typically require a highly reliable power supply, redundant arrangements, and close monitoring. The transformer rating should be consistent with the documented load and the role of each unit in that arrangement.

The listed capacity range is 500–2,500 kVA, and customized capacity is available. The product information does not provide a sizing formula or specify overload capability. For that reason, the project team should confirm the required rating with its electrical calculations and the supplier’s technical drawing.

Match the Transformer to the Electrical System

Voltage, Frequency, and Connections

Available voltage options are 6, 11, 13.8, 15, and 20 kV, with customized types also available. The transformer is specified for three-phase operation at either 50 Hz or 60 Hz. Verify these values against the site supply and the approved system design.

Listed vector groups are Dyn11 and Yyn11. The selected connection must suit the project’s electrical arrangement and protection requirements. Review the primary and secondary details in the technical drawings before confirming the order.

Cooling, Insulation, and Voltage Adjustment

The listed cooling methods are AN and AF, while insulation class options are F and H. Choose the combination required by the installation and design conditions. The stated insulation level is LI/AC-125/50 kV and should be checked against the project specification.

The standard tap arrangement is ±2 × 2.5%, with an on-load tap changer (OLTC) available as an option. Confirm the required tap arrangement with the supplier. Although the product is described as low noise, no acoustic performance figures are stated; request confirmation of any project-specific noise limit.

Low noise epoxy resin indoor dry type transformer for data center applications

Dry Type Transformer Selection Checklist

Selection factorListed specificationProject review
Capacity500–2,500 kVA or customizedConfirm against backup demand and the planned redundancy configuration
Voltage and frequency6, 11, 13.8, 15, or 20 kV; customized voltage; 50 or 60 HzCheck compatibility with the site supply and drawings
Cooling and insulationAN or AF cooling; class F or H insulationSpecify the combination required for the installation
Connections and tapsDyn11 or Yyn11; ±2 × 2.5% standard taps or optional OLTCReview connection, protection, and voltage adjustment requirements
Inspection and deliveryFAT, routine and type testing, and pre-shipment inspection; 45–60 working days after deposit and drawing confirmationAgree on the inspection scope and confirm the schedule after technical approval

Review Standards, Testing, and Documentation

The product information lists IEC, IEEE, ANSI, GOST, NEMA, CE, and ISO among its standards. It describes factory acceptance testing (FAT), routine testing, type testing, and full inspection before shipment, with compliance stated for IEEE and IEC. Agree on the applicable standards, inspection scope, and documentation for the specific order.

Company records also list UDEM certification covering substations, transformers, and switchgear, as well as CNAS accreditation for testing an oil-immersed transformer model. The CNAS document provides technical support and does not replace mandatory local certification for the selected equipment.

The company reports a separate utility project in Madagascar involving two 25 MVA, 63/35 kV power transformers for a substation renovation. That project is distinct from the dry type model described here and does not establish its performance.

Frequently Asked Questions

What transformer capacity is available for backup loads?

The listed range is 500–2,500 kVA, with customized capacity available. The appropriate rating depends on the project’s load calculation and backup system configuration.

Can the transformer be specified for different site supplies?

Yes. Listed voltage options are 6, 11, 13.8, 15, and 20 kV, with customized types available. The listed frequency options are 50 Hz and 60 Hz. Confirm the required values in the approved technical drawings.

What testing and support does the supplier list?

The listing includes FAT, routine testing, type testing, and full inspection before shipment. It also states a 72-hour global technical response, on-site commissioning and training, spare-parts supply, and remote diagnostics.

Confirm the Specification Before Ordering

Use the approved load schedule and electrical design to settle the capacity, voltage, frequency, cooling, insulation, vector group, and tap arrangement. Confirm the drawings and inspection scope with the supplier. The stated lead time is 45–60 working days after deposit and drawing confirmation. Vziman lists manufacturer, OEM and ODM, and turnkey project supply models. For technical solutions or support, contact support@vziman.com.

About Vziman

Zhejiang Vziman Electric Power Technology Co., Ltd. is the parent company of Zhejiang Vziman Electric Group Co., Ltd. Its predecessor companies trace back to Zhejiang Powertech Electric Co., Ltd., founded in 2014. The group develops, manufactures, and services transformers, switchgear, distribution equipment, power automation systems, and other electrical power equipment. It states that its R&D team includes more than 30 senior electrical engineers and industrial designers and that its markets span more than 100 countries. The company lists UDEM and CNAS-related credentials and reports utility projects in Madagascar, the Dominican Republic, and Suriname.