Buyers can arrange an inspection of a working Compact Prefabricated Substation before proceeding with a bulk purchase. For Vziman’s three-phase solar substation, factory acceptance testing (FAT), customer witness inspections, and third-party testing can be requested. Since the minimum order quantity is one set, purchasers may also discuss whether the inspected unit will be a sample, a production unit, or the actual equipment included in the order.
A factory inspection should be planned before the purchase order is finalized. The supplier states that each applicable compact substation can undergo a full factory acceptance test, with a test report provided after completion. Buyers may attend the test in person, appoint an independent inspection organization, or request both arrangements where appropriate.
To avoid misunderstandings, the inspection plan should identify the equipment model, approved technical drawings, test items, acceptance standards, attendee responsibilities, and reporting requirements. This is especially important when the substation includes non-standard voltage ratings, capacity requirements, or other customized design elements.
The product is presented as a three-phase compact prefabricated substation designed for photovoltaic and wind-energy systems. Standard capacity selections are listed from 1,000 kVA to 3,000 kVA, while customized capacities can also be discussed. Available medium-voltage levels include 11 kV, 20 kV, 22 kV, and 34.5 kV, with customized specifications available for project-specific requirements.
The stated reference standards include IEC, IEEE, ANSI, GOST, NEMA, ECO, MEPS, ESKOM, MS, JEC, and TEIAS. Buyers should verify which of these standards, test methods, and documentation requirements apply to their final substation design before production begins.

| Planning area | Available product information | Recommended buyer step |
|---|---|---|
| Factory acceptance test | Full factory testing and a test report are stated as available. | Ask for the proposed test procedure, checkpoints, and report template. |
| Inspection participation | Witness inspection and third-party testing are supported. | Confirm the inspector, attendance date, and inspection responsibilities in advance. |
| Electrical ratings | 1,000–3,000 kVA and 11, 20, 22, or 34.5 kV options are listed, with customization available. | Match the test plan to the approved drawings and final technical schedule. |
| Order quantity | The minimum order quantity is one set. | Clarify whether the inspected equipment is a sample or part of the delivered order. |
| Lead time | Standard models are listed at 30–45 working days; customized units require 45–70 working days after drawing approval. | Reserve inspection time before the planned shipment date. |
Zhejiang Vziman Electric Power Technology Co., Ltd. is identified as the parent company of Zhejiang Vziman Electric Group Co., Ltd. Its profile describes activities covering research and development, manufacturing, and service for power electrical equipment. The company reports a team of more than 30 senior electrical engineers and industrial designers, as well as standardized manufacturing workshops with established production and testing workflows.
The company profile lists UDEM certification for substations, transformers, and switchgear, together with CNAS accreditation for test results associated with a specified oil-immersed power transformer. It also references projects such as a photovoltaic-station grounding transformer installation in Nigeria and a transformer project for grid renovation in Madagascar. These projects demonstrate related power-equipment experience, but they should not be interpreted as independent performance verification for a particular compact substation configuration.
Yes. The available product information indicates that factory acceptance testing, witness inspection, and third-party testing can be arranged. Inspection details should be agreed with the supplier before order confirmation.
Customized capacity and medium-voltage options are available. Because the inspection process for a customized design is not separately defined, buyers should ensure that the test plan is based on the approved drawings and final specifications.
Buyers should request the factory test plan, applicable acceptance criteria, test report, approved drawings, and any project-specific documentation required for delivery or regulatory review.
Inspecting a Compact Prefabricated Substation before making a volume commitment is possible through factory acceptance testing, buyer witness arrangements, or an independent third-party inspection. The most effective approach is to define the unit configuration, standards, testing scope, schedule, and report deliverables before production is completed. Vziman lists manufacturer, OEM and ODM, and turnkey project supplier business models for this product category. For technical coordination, contact support@vziman.com.
Zhejiang Vziman Electric Power Technology Co., Ltd. is the parent company of Zhejiang Vziman Electric Group Co., Ltd., focusing on the R&D, production, and service of power electrical equipment. Its stated business areas include switchgear, power distribution equipment, electrical automation systems, and engineering services. The company profile also cites a technical team of more than 30 senior electrical engineers and industrial designers, alongside listed UDEM and CNAS credentials.

REPORT