Before approving mass production, evaluate the slim glass-door frame sample as a complete door system. Compare the 6063 T5 aluminium profile, frame dimensions, glass seating, surface finish, hardware positioning, joint quality, and door operation with the approved drawings or reference sample. Document every result and release production only after all acceptance criteria have been met.
Inspection should begin with the approved technical reference. Confirm the sample identity, profile configuration, finish, glass specification, hardware arrangement, and frame dimensions before checking individual components. A slim aluminium frame may look correct as a loose extrusion but still fail when assembled with the glass, connectors, rollers, hinges, handles, or other accessories.
The listed material is 6063 T5 aluminium, while the product information indicates a minimum order quantity of 1 and a stated 30-day delivery period. These details make a single sample suitable for preliminary verification before a larger order is placed. The approved sample should become the visual, dimensional, and functional benchmark for subsequent production.

Check the aluminium profile against the approved drawing and reference sample. Review the frame width, height, component lengths, connection details, corner alignment, and overall squareness. Machined areas should be clean, with no burrs, distortion, or unfinished edges. After assembly, confirm that joints are firm and that the frame remains stable when handled and operated.
Install the intended glass in accordance with the approved system. The glass should sit securely and evenly in the frame without looseness, pressure points, rattling, or visible interference. Check that hinges, rollers, handles, guides, seals, and other hardware are positioned correctly and do not obstruct the glass or frame. Since the available product information does not state the glass thickness or hardware tolerances, these points should be confirmed from the project drawing or technical specification.
Examine the finished sample under consistent, normal lighting. Look for scratches, dents, machining traces, coating variation, uneven color, surface contamination, and other visible defects. Then operate the completed door repeatedly. Depending on the design, verify smooth opening and closing or stable sliding travel, consistent clearances, correct stopping points, and the absence of rubbing, excessive noise, binding, or unexpected movement.
Record the sample number, material designation, profile configuration, measured dimensions, finish condition, glass fit, hardware alignment, assembly status, operating results, and any required revisions. An unresolved deviation should be classified and corrected before the sample is accepted as the production standard.
| Inspection Area | What to Verify | Recommended Decision |
|---|---|---|
| Material and profile | Confirm the 6063 T5 designation and compare the extrusion shape and configuration with the approved reference. | Approve only when the material and profile system correspond to the specification. |
| Frame size and joints | Review dimensions, squareness, component fit, machining, alignment, and joint strength. | Place approval on hold until unresolved differences are corrected. |
| Glass connection | Check secure seating, even clearances, stable retention, and freedom from interference or movement. | Approve when the glass integrates correctly with the complete frame system. |
| Surface treatment | Inspect for scratches, dents, machining marks, coating inconsistency, dirt, and color variation. | Request repair, refinishing, or replacement for unacceptable visible defects. |
| Door operation | Test opening, closing, or sliding movement and confirm proper hardware coordination. | Approve when operation is smooth, repeatable, and unobstructed. |
Which information should be confirmed before the sample is tested?
Confirm the wardrobe door aluminium system, 6063 T5 material designation, approved drawings or reference sample, surface finish, glass arrangement, hardware package, and intended operating method. The current product data do not specify profile dimensions, glass thickness, or dimensional tolerances, so these requirements must come from the project documentation.
Is one sample sufficient for an initial review?
Yes. The product listing states an MOQ of 1, so one representative sample can be assessed before mass production. It should include the intended profile, finish, glass interface, connectors, and operating hardware rather than being evaluated only as an unfinished extrusion.
How should a mismatch be handled?
Describe the deviation in the approval record and identify whether it relates to material, dimensions, finish, assembly, glass fit, hardware, or performance. Request clarification or correction and repeat the relevant inspection before granting production approval.
Mass production should proceed only when the slim glass-door frame sample satisfies the documented requirements for 6063 T5 aluminium, dimensions, joints, surface quality, glass installation, hardware alignment, and door movement. The sample information lists an MOQ of 1 with a 30-day delivery time. MEBEL-ALU also supports FOB cooperation with an MOQ of 12000KG and a stated 40-day delivery time. Its Quality Management System Certificate and Occupational Health and Safety Management System Certificate provide additional evidence of formal management processes. For technical assistance or project support, contact mebel@mebel-alu.com.
Mebel-Alu Furniture Profile (Hong Kong) Co., Ltd has developed precision aluminium profile solutions for contemporary interiors since 2008. Its product range includes aluminium glass-door systems, sliding wardrobe frames, kitchen cabinet profiles, and decorative tile trims. The company operates a 300000 Sqm factory with in-house extrusion, anodizing, brushing, mechanical polishing, and CNC machining capabilities. Its R&D work covers home furnishing, cabinet, and door trends, together with aluminium accessories and integrated hardware packages. Listed credentials include the Quality Management System Certificate and the Occupational Health and Safety Management System Certificate.